bft hydraulic gate problem

13 May.,2024

 

bft hydraulic gate problem

(18-05-2017, 08:18 AM)

bft hydraulic gatehydraulic gate problem

(18-05-2017, 08:18 AM)

richh Wrote: Hi all i am a complete noob on this forum, please forgive if i am in the wrong thread... My gate doesnt open or close properley first thing in the morning, once it has attempted two three times it then work ok all day , has anyone any idea's? please regards Richard

Hi, we have the same problem in BFT LUX BT 2B - hidraulic sistem, at 5 years ago.
We have this problem since we have bought this.
But the problem just appear in winter when is very cold, so in morning this have error when try to close, in afternoon everithing is oright or in summer.

We can close, if after error apper we click in open again, and 1 second after we click in close again, so this passe the error zone. we the error apperar again, we do the same again, and normely in 1 or 2 times, we can close the gate.

So our question is, have you found the problem?

Thanks for your help...

Hi, we have the same problem in BFT LUX BT 2B - hidraulic sistem, at 5 years ago.We have this problem since we have bought this.But the problem just appear in winter when is very cold, so in morning this have error when try to close, in afternoon everithing is oright or in summer.We can close, if after error apper we click in open again, and 1 second after we click in close again, so this passe the error zone. we the error apperar again, we do the same again, and normely in 1 or 2 times, we can close the gate.So our question is, have you found the problem?Thanks for your help...

What To Know Before You Install An Automatic Gate Opener

Installation Troubleshooting
7 minute read

Audio is generated by DropInBlog's AI and may have slight pronunciation nuances. Learn more

Before you install, Ghost Controls®’ Automatic Gate Openers are meant to be used in agricultural and single-family residential applications.

Gate Considerations:

  • Before you install, make sure the gate swings level, plumb, and freely throughout the full opening and closing range of motion. (Level is horizontal and plumb is vertical).
  • This may require making sure the gate post is plumb and/or adjusting/positioning the gate hinges to be aligned vertically.
  • When a gate/post is not plumb it may surge/hesitate in a particular direction of its travel and possibly not function.
  • When a driveway single swing gate is not level it may drag the ground or cause a bind in some manner.

Freely swinging gates are crucial to ensuring that your single or dual gate opener system works correctly. If the gate(s) weighs more than 200lbs, bearing-type hinges should be used. If your ball-bearing/bearing type gate hinges are binding, out of grease, or have become difficult to move, your remote gate opener system may treat this as an obstruction.

This can likely be resolved by lubricating your gate hinges. If the hinges are worn or damaged replace them

The use of guy wires and or wheels to help support/facilitate gate movement is not recommended. These cause the control arm(s) to encounter different amounts of resistance during motion and may cause the unit to believe it has come in contact with an obstruction and momentarily reverse direction.

If the unit is being installed on a tube-style gate, our AXTB Universal Tube Bracket Kit can make the installation a bit easier. Some kits already include these brackets. Please read the list of hardware included with your kit, and assess your individual needs.

Direction of Gate Travel:

  • Pull to Open means the Gate(s) opens to the inside of the property.
  • Push to Open means the Gate(s) opens to the outside of the property, and the purchase of our AXPO Push-To-Open Brackets will be required
  • The AXPO push bracket kit is a set of 2.
  • For dual gate applications, two sets will need to be purchased.

Do you have a solid panel gate (which is considered to be any gate with more than 30% surface coverage)? We do not recommend using our gate operators on gates of this kind, because any full panel gate with a swing operator attached has the potential to catch a gust of wind and cause irreparable damage to the gate and gate operator.

If you still choose to install our system on a full panel gate, we will honor the warranty for your accessories and control board, BUT we will NOT be able to honor the warranty on your gate opener arm and mounting hardware. Please give us a call if you have further questions.

Running the secondary operator arm in conduit makes maintenance and any future service issues much easier.

Gate Posts:

  • All posts need to be secured with concrete.
  • Wooden gate posts should be at least 6x6”.
  • Metal Round posts should be at least 3” in diameter.
  • Metal Square posts should be at least 4x4”.

Column considerations: The below diagrams concern gates that open to the inside of the property.

  • If your column and the manner in which the electric driveway gate is hinged exceed the below guidelines, you can install the swing gate operator system as a Push to Open.
  • If your gate is already a push to open style or you intend to make it so, the purchase of our AXPO Push-To-Open Brackets will be required.
  • If you are unable to configure your gate as a Push to Open system, give us a call at 850-558-5520 for assistance.

Solar Power Requirements:

This is a battery-operated system. 12 Volt Battery(s) are required. You choose how you will maintain the battery(s): Solar OR Transformer.

For units being installed with solar panels:

The minimum recommendation is Two 12V, 7AH batteries. The best option - to remain operational during intermittent long unusual periods with little or no sunlight - is a Marine Deep Cycle type battery. Marine-type batteries differ in ways that allow them to continue to work longer under adverse conditions. However, this is not a cure for lack of direct sunlight due to panel placement or an obstruction (trees, shrubs, etc.).

Chronic low battery issues stem from the lack of enough consistent charge. This is overcome by:

  • Panel placement.
  • Receiving the minimal direct sunlight requirements.
  • Having the right amount of panels based on your location and application. Please see our Solar Panel Chart below for more details.

If needed, the solar panel(s) can be positioned up to 100’ away from the control box by extending the wire using 16 gauge stranded, 2-conductor low voltage wire. If extended, the splices will need to be weatherproof.

For units being installed with a transformer (AC Power):

One 12V, 7AH battery is the minimum requirement. The transformer will be plugged into a 120-volt outlet. The transformer must be protected from the weather indoors or in a weatherproof outdoor box/cover. Once the transformer is plugged in, the wire from the transformer (not supplied) to the control box can not exceed 1000’. The recommended wire is a 16 gauge stranded, 2-conductor low voltage.

Pedestrian Gates:

We include the need for a pedestrian gate as a requirement because Ghost Controls® systems are intended for vehicular access and not for pedestrian use. Having a separate walk-through gate gives you easy access to your property, especially in the unfortunate event that your system does not open on command. If this were to occur, use the pedestrian gate to enter the property and you can manually open or close your automatic gate opener as described in your installation manual.

For further information or help choosing a system, give us a call at (850) 558-5520.

Use the tools below to print or download "What to know before you install a Ghost Controls® Automatic Gate Opener System"

Looking to learn more about Ghost Controls® solar gate openers and gate opener accessories? 

Ghost Controls offers a wide array of reliable driveway swing gate openers, including chain link gate openers. For years, customers have asked for an alternative for slow, unreliable, and noisy operators. At Ghost Controls we have worked hard with innovations in Noise Reduction, Speed, and Reliability on our heavy duty electric gate openers. Additionally, we provide all of our customers with the opportunity to share our love of solar powered renewable energy by converting their systems into a solar automatic gate opener. Using a solar operator is a great way to go off the grid and provide your system with endless clean energy for your remote gate opener.

Speed, and Reliability:

  • Quiet

     – motor noise is accurately correlated to quality in the mechanical and electronic design. All our openers have a maintenance free gear box and motor. They were designed for smooth, quiet operation regardless of the age and cycles of the battery powered gate opener.
  • Fast

     – Our mechanical design and new radio frequency offer superior range offering a greater level of convenience for customers.
  • Invincible (Limited Life-Time Warranty)

     – The motor is one of the most critical components to ensure reliability and longevity. We back our proprietary gear motors with a limited lifetime warranty. No other product in the market can make this claim.

GHOST CONTROLS® single and double swing gate openers are designed and manufactured with pride, delivering the highest quality product and customer support in the industry. We believe in our products with our limited lifetime warranty on each solar compatible dual or single gate opener*. Our corporate philosophy is; steadfast commitment to our customers, culture, products, and people.

*Limited lifetime warranty on motor and gear assembly.

richh Wrote: Hi all i am a complete noob on this forum, please forgive if i am in the wrong thread... My gate doesnt open or close properley first thing in the morning, once it has attempted two three times it then work ok all day , has anyone any idea's? please regards Richard

Hi, we have the same problem in BFT LUX BT 2B - hidraulic sistem, at 5 years ago.
We have this problem since we have bought this.
But the problem just appear in winter when is very cold, so in morning this have error when try to close, in afternoon everithing is oright or in summer.

We can close, if after error apper we click in open again, and 1 second after we click in close again, so this passe the error zone. we the error apperar again, we do the same again, and normely in 1 or 2 times, we can close the gate.

So our question is, have you found the problem?

Thanks for your help...

Hi, we have the same problem in BFT LUX BT 2B - hidraulic sistem, at 5 years ago.We have this problem since we have bought this.But the problem just appear in winter when is very cold, so in morning this have error when try to close, in afternoon everithing is oright or in summer.We can close, if after error apper we click in open again, and 1 second after we click in close again, so this passe the error zone. we the error apperar again, we do the same again, and normely in 1 or 2 times, we can close the gate.So our question is, have you found the problem?Thanks for your help...

What To Know Before You Install An Automatic Gate Opener

Installation Troubleshooting
7 minute read

Audio is generated by DropInBlog's AI and may have slight pronunciation nuances. Learn more

Before you install, Ghost Controls®’ Automatic Gate Openers are meant to be used in agricultural and single-family residential applications.

Gate Considerations:

  • Before you install, make sure the gate swings level, plumb, and freely throughout the full opening and closing range of motion. (Level is horizontal and plumb is vertical).
  • This may require making sure the gate post is plumb and/or adjusting/positioning the gate hinges to be aligned vertically.
  • When a gate/post is not plumb it may surge/hesitate in a particular direction of its travel and possibly not function.
  • When a driveway single swing gate is not level it may drag the ground or cause a bind in some manner.

Freely swinging gates are crucial to ensuring that your single or dual gate opener system works correctly. If the gate(s) weighs more than 200lbs, bearing-type hinges should be used. If your ball-bearing/bearing type gate hinges are binding, out of grease, or have become difficult to move, your remote gate opener system may treat this as an obstruction.

This can likely be resolved by lubricating your gate hinges. If the hinges are worn or damaged replace them

The use of guy wires and or wheels to help support/facilitate gate movement is not recommended. These cause the control arm(s) to encounter different amounts of resistance during motion and may cause the unit to believe it has come in contact with an obstruction and momentarily reverse direction.

If the unit is being installed on a tube-style gate, our AXTB Universal Tube Bracket Kit can make the installation a bit easier. Some kits already include these brackets. Please read the list of hardware included with your kit, and assess your individual needs.

Direction of Gate Travel:

  • Pull to Open means the Gate(s) opens to the inside of the property.
  • Push to Open means the Gate(s) opens to the outside of the property, and the purchase of our AXPO Push-To-Open Brackets will be required
  • The AXPO push bracket kit is a set of 2.
  • For dual gate applications, two sets will need to be purchased.

Do you have a solid panel gate (which is considered to be any gate with more than 30% surface coverage)? We do not recommend using our gate operators on gates of this kind, because any full panel gate with a swing operator attached has the potential to catch a gust of wind and cause irreparable damage to the gate and gate operator.

If you still choose to install our system on a full panel gate, we will honor the warranty for your accessories and control board, BUT we will NOT be able to honor the warranty on your gate opener arm and mounting hardware. Please give us a call if you have further questions.

Running the secondary operator arm in conduit makes maintenance and any future service issues much easier.

Gate Posts:

  • All posts need to be secured with concrete.
  • Wooden gate posts should be at least 6x6”.
  • Metal Round posts should be at least 3” in diameter.
  • Metal Square posts should be at least 4x4”.

Column considerations: The below diagrams concern gates that open to the inside of the property.

  • If your column and the manner in which the electric driveway gate is hinged exceed the below guidelines, you can install the swing gate operator system as a Push to Open.
  • If your gate is already a push to open style or you intend to make it so, the purchase of our AXPO Push-To-Open Brackets will be required.
  • If you are unable to configure your gate as a Push to Open system, give us a call at 850-558-5520 for assistance.

Solar Power Requirements:

This is a battery-operated system. 12 Volt Battery(s) are required. You choose how you will maintain the battery(s): Solar OR Transformer.

For units being installed with solar panels:

The company is the world’s best dam construction companies supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

The minimum recommendation is Two 12V, 7AH batteries. The best option - to remain operational during intermittent long unusual periods with little or no sunlight - is a Marine Deep Cycle type battery. Marine-type batteries differ in ways that allow them to continue to work longer under adverse conditions. However, this is not a cure for lack of direct sunlight due to panel placement or an obstruction (trees, shrubs, etc.).

Chronic low battery issues stem from the lack of enough consistent charge. This is overcome by:

  • Panel placement.
  • Receiving the minimal direct sunlight requirements.
  • Having the right amount of panels based on your location and application. Please see our Solar Panel Chart below for more details.

If needed, the solar panel(s) can be positioned up to 100’ away from the control box by extending the wire using 16 gauge stranded, 2-conductor low voltage wire. If extended, the splices will need to be weatherproof.

For units being installed with a transformer (AC Power):

One 12V, 7AH battery is the minimum requirement. The transformer will be plugged into a 120-volt outlet. The transformer must be protected from the weather indoors or in a weatherproof outdoor box/cover. Once the transformer is plugged in, the wire from the transformer (not supplied) to the control box can not exceed 1000’. The recommended wire is a 16 gauge stranded, 2-conductor low voltage.

Pedestrian Gates:

We include the need for a pedestrian gate as a requirement because Ghost Controls® systems are intended for vehicular access and not for pedestrian use. Having a separate walk-through gate gives you easy access to your property, especially in the unfortunate event that your system does not open on command. If this were to occur, use the pedestrian gate to enter the property and you can manually open or close your automatic gate opener as described in your installation manual.

For further information or help choosing a system, give us a call at (850) 558-5520.

Use the tools below to print or download "What to know before you install a Ghost Controls® Automatic Gate Opener System"

Looking to learn more about Ghost Controls® solar gate openers and gate opener accessories? 

Ghost Controls offers a wide array of reliable driveway swing gate openers, including chain link gate openers. For years, customers have asked for an alternative for slow, unreliable, and noisy operators. At Ghost Controls we have worked hard with innovations in Noise Reduction, Speed, and Reliability on our heavy duty electric gate openers. Additionally, we provide all of our customers with the opportunity to share our love of solar powered renewable energy by converting their systems into a solar automatic gate opener. Using a solar operator is a great way to go off the grid and provide your system with endless clean energy for your remote gate opener.

Speed, and Reliability:

  • Quiet

     – motor noise is accurately correlated to quality in the mechanical and electronic design. All our openers have a maintenance free gear box and motor. They were designed for smooth, quiet operation regardless of the age and cycles of the battery powered gate opener.
  • Fast

     – Our mechanical design and new radio frequency offer superior range offering a greater level of convenience for customers.
  • Invincible (Limited Life-Time Warranty)

     – The motor is one of the most critical components to ensure reliability and longevity. We back our proprietary gear motors with a limited lifetime warranty. No other product in the market can make this claim.

GHOST CONTROLS® single and double swing gate openers are designed and manufactured with pride, delivering the highest quality product and customer support in the industry. We believe in our products with our limited lifetime warranty on each solar compatible dual or single gate opener*. Our corporate philosophy is; steadfast commitment to our customers, culture, products, and people.

*Limited lifetime warranty on motor and gear assembly.

Are you interested in learning more about flow control gate? Contact us today to secure an expert consultation!